Quick answer: Steel grating weight per square metre = 7.85 × H × t ÷ P (bearing bars) + 7.85 × A ÷ C (cross bars), where H and t are the bearing bar height and thickness, P is the bearing bar pitch, A is the cross bar area in mm² and C is the cross bar pitch, all in mm. A common 32 × 5 mm grating at 30 × 100 mm pitch weighs about 44.7 kg/m² before galvanizing and about 48 kg/m² as GI grating.
GI grating is bought, transported, lifted and designed by weight. A contractor needs the weight to price a platform, a fabricator needs it to plan crane lifts, and a structural engineer needs it as dead load on the supporting beams. Yet most grating charts online just list numbers without saying which cross bar or coating they assume, so two charts for the same “32 × 5” grating can disagree.
This guide from SteelCal.com shows the formula behind every grating weight chart, gives a full weight table for the most-used sizes, works through real examples step by step, and explains how bar size and span affect load capacity. A free grating weight calculator is included below.
What is GI grating?
GI grating (galvanized iron grating) is welded steel bar grating that has been hot-dip galvanized for corrosion protection. It is an open grid of flat bearing bars standing on edge, held in place by cross bars (usually twisted square bars) welded across the top. The same product before galvanizing is called MS grating, black grating or self-colour grating.
Grating terms you need to know
| Term | Meaning | Typical values |
|---|---|---|
| Bearing bar (load bar) | The flat bars on edge that carry the load across the span | 20 × 3 to 50 × 5 mm (height × thickness) |
| Bearing bar pitch | Centre-to-centre distance between bearing bars | 30 mm or 40 mm (others on request) |
| Cross bar | Bars welded across the bearing bars to hold them upright | Twisted square bar, often 5–8 mm |
| Cross bar pitch | Centre-to-centre distance between cross bars | 100 mm or 50 mm |
| Span | Clear distance between supports, always measured along the bearing bars | Depends on load — see the load section below |
| Banding (binding bar) | Flat bar welded around cut edges and openings | Usually same size as the bearing bar |
| Surface | Plain top, or serrated (notched) top for slip resistance | Plain or serrated |
A specification such as “32 × 5 @ 30 × 100, serrated, HDG” means 32 mm high × 5 mm thick bearing bars at 30 mm centres, cross bars at 100 mm centres, serrated top and hot-dip galvanized.
How do you calculate steel grating weight?
Grating weight is the weight of its bars, so it uses the same rule as any steel section: weight = volume × density, with mild steel at 7,850 kg/m³ (7.85 kg per metre for every 1,000 mm² of section).
Formula for weight per square metre (black / MS grating)
- W = theoretical weight of black grating, kg/m²
- H = bearing bar height, mm
- t = bearing bar thickness, mm
- P = bearing bar pitch (centre to centre), mm
- A = cross bar cross-section area, mm² (a 6 mm square bar = 36 mm²)
- C = cross bar pitch, mm
- 7.85 = density of mild steel in g/cm³
Why it works: one metre of bar with area H × t mm² weighs H × t × 0.00785 kg. A 1-metre-wide panel contains 1,000 ÷ P bearing bars, so the bearing bars weigh (1,000 ÷ P) × H × t × 0.00785 = 7.85 × H × t ÷ P kg per m². The cross bars follow the same logic in the other direction.
Adding the galvanizing (GI grating)
Hot-dip galvanizing adds zinc to every face of every bar. The minimum average coating in ISO 1461 is 70 µm for steel over 3 mm up to 6 mm thick and 85 µm above 6 mm. On a typical grating this minimum alone adds roughly 3%, but real coatings are usually thicker than the minimum and zinc collects at the welds. Published manufacturer tables add between about 6% and 14%. For estimating, SteelCal uses:
Weight of a whole panel
Banding weight = total banded edge length (m) × H × t × 0.00785. Add the galvanizing allowance after adding the banding.
GI grating weight chart (kg/m²)
The chart below is calculated with the formula above, using a 6 mm twisted square cross bar at 100 mm pitch (2.83 kg/m²) and mild steel density 7.85 g/cm³. The GI column applies the 8% galvanizing allowance. Values are theoretical, unbanded, plain-top weights.
| Bearing bar (H × t, mm) | Pitch 30 × 100 mm | Pitch 40 × 100 mm | ||
|---|---|---|---|---|
| Black (kg/m²) | GI ≈ (kg/m²) | Black (kg/m²) | GI ≈ (kg/m²) | |
| 20 × 3 | 18.5 | 20.0 | 14.6 | 15.8 |
| 20 × 5 | 29.0 | 31.3 | 22.4 | 24.2 |
| 25 × 3 | 22.4 | 24.2 | 17.5 | 18.9 |
| 25 × 5 | 35.5 | 38.4 | 27.4 | 29.5 |
| 30 × 3 | 26.4 | 28.5 | 20.5 | 22.1 |
| 30 × 5 | 42.1 | 45.4 | 32.3 | 34.8 |
| 32 × 3 | 28.0 | 30.2 | 21.7 | 23.4 |
| 32 × 5 | 44.7 | 48.3 | 34.2 | 37.0 |
| 40 × 3 | 34.2 | 37.0 | 26.4 | 28.5 |
| 40 × 5 | 55.2 | 59.6 | 42.1 | 45.4 |
| 50 × 5 | 68.2 | 73.7 | 51.9 | 56.0 |
Why other charts differ slightly: manufacturers use different cross bars (5, 6 or 8 mm, round or twisted). A heavier cross bar adds about 1–2 kg/m². Serrated bars lose a little steel at the notches, so serrated grating of the same bar size is slightly lighter. Always use the supplier’s figure for final load calculations.
Worked examples
Example 1: Weight per m² of 32 × 5 @ 30 × 100 grating
- Bearing bars: 7.85 × 32 × 5 ÷ 30 = 41.87 kg/m²
- Cross bars (6 mm square, A = 36 mm², C = 100 mm): 7.85 × 36 ÷ 100 = 2.83 kg/m²
- Black grating: 41.87 + 2.83 = 44.70 kg/m²
- GI grating: 44.70 × 1.08 ≈ 48.3 kg/m²
Example 2: A standard 1 m × 6 m GI grating panel
- Black weight of the mesh: 44.70 × 1 × 6 = 268.2 kg
- Banding on the two 1 m cut ends (32 × 5 flat bar): 2 × 1 × 32 × 5 × 0.00785 = 2.5 kg
- Total black: 268.2 + 2.5 = 270.7 kg
- Galvanized: 270.7 × 1.08 ≈ 292 kg per panel — enough to need lifting equipment, not hand carrying.
Example 3: A drain cover 600 × 1000 mm in 25 × 5 grating
- Area: 0.6 × 1.0 = 0.6 m²
- Black: 35.53 × 0.6 = 21.3 kg
- GI: 21.3 × 1.08 ≈ 23 kg (plus banding around all four edges if specified)
Remember that the bearing bars must run across the 600 mm drain opening — the span direction — not along it.
Example 4: Ordering grating for a 4 m × 3 m platform
- Area: 4 × 3 = 12 m²
- GI weight with 32 × 5 @ 30 × 100: 12 × 48.3 ≈ 580 kg
- Add the weight of cut-outs’ banding and an allowance for offcuts when panels are cut from 1 × 6 m stock.
Free grating weight calculator
Enter your bar sizes and panel size. The calculator uses the same formula as the chart above.
Banding is not included. For plates, pipes, tubes and beams, use the SteelCal metal weight calculator.
How much load can GI grating carry?
Load capacity depends on the bearing bars only: their height, thickness, pitch and the span. Height matters most — bending strength grows with the square of bar height and stiffness with its cube. That is why a 40 × 5 bar is far stronger than a 32 × 5 bar, even though it is only about 25% heavier.
Load formulas (simply supported span)
These are the standard beam formulas used in the NAAMM MBG 534 metal bar grating design manual, written here per 1 metre of grating width:
S = n × t × H² ÷ 6 (section modulus, mm³)
I = n × t × H³ ÷ 12 (moment of inertia, mm⁴)
M = F × S (allowable moment, N·mm)
U = 8 × M ÷ L² (allowable uniform load, kN/m², L in mm)
Deflection δ = 5 × w × L⁴ ÷ (384 × E × I) (w in kN/m² = N/mm per metre width)
F is the allowable bending stress — NAAMM uses 137.9 MPa (20,000 psi) for ASTM A36 bars and 124.1 MPa for A1011 CS Type B — and E = 200,000 MPa for steel.
Worked example: 32 × 5 @ 30 on a 1.2 m span
- n = 1000 ÷ 30 = 33.3 bars per metre
- S = 33.3 × 5 × 32² ÷ 6 = 28,444 mm³; I = 33.3 × 5 × 32³ ÷ 12 = 455,111 mm⁴
- M = 137.9 × 28,444 = 3.92 kN·m per metre width
- U = 8 × 3.92 × 10⁶ ÷ 1,200² ≈ 21.8 kN/m² (stress limit)
- Deflection under a 5 kN/m² walkway load: 5 × 5 × 1,200⁴ ÷ (384 × 200,000 × 455,111) ≈ 1.5 mm
Indicative uniform load capacity, pitch 30 mm (theoretical)
| Bearing bar | Span 900 mm | Span 1200 mm | Span 1500 mm | Span 1800 mm |
|---|---|---|---|---|
| 25 × 5 | 23.6 kN/m² (1.0 mm) | 13.3 kN/m² (3.1 mm) | 8.5 kN/m² (7.6 mm) | 5.9 kN/m² (15.8 mm) |
| 32 × 5 | 38.7 kN/m² (0.5 mm) | 21.8 kN/m² (1.5 mm) | 13.9 kN/m² (3.6 mm) | 9.7 kN/m² (7.5 mm) |
| 40 × 5 | 60.5 kN/m² (0.2 mm) | 34.0 kN/m² (0.8 mm) | 21.8 kN/m² (1.9 mm) | 15.1 kN/m² (3.8 mm) |
| 50 × 5 | 94.6 kN/m² (0.1 mm) | 53.2 kN/m² (0.4 mm) | 34.0 kN/m² (1.0 mm) | 23.6 kN/m² (2.0 mm) |
Allowable stress 137.9 MPa, simply supported. Brackets = deflection under 5 kN/m². Grating self-weight not included. As spans get longer, deflection usually governs before strength: NAAMM recommends limiting deflection to 6 mm (¼ in) for pedestrian comfort. These are educational estimates, not certified load tables — for design, use the manufacturer's tested load tables and your project's standard (for example BS 4592 in the UK and Gulf, or ANSI/NAAMM MBG 531 in the US).
Plain vs serrated GI grating
| Plain grating | Serrated grating | |
|---|---|---|
| Top surface | Flat bar edges | Notched bar edges |
| Slip resistance | Standard | Better on wet, oily or sloped areas |
| Weight (same bar) | Reference | Slightly lighter |
| Load capacity | Full bar height counts | Notches reduce effective height — use serrated load tables |
| Typical use | Covers, mezzanines, indoor walkways | Stairs, offshore, plant platforms, outdoor walkways |
Where is GI grating used?
- Walkways and platforms in factories, warehouses, power and water plants
- Drain and trench covers — choose heavier bars and closer pitch where vehicles cross
- Stair treads with a chequered or abrasive nosing
- Mezzanine floors and catwalks where light, air and water must pass through
- Plant room and rooftop equipment screens
Galvanizing is the normal choice in coastal and humid climates such as the UAE and the wider Gulf, because bare steel grating rusts quickly outdoors.
Common mistakes when calculating grating weight
- Swapping height and thickness. "32 × 5" means 32 mm high and 5 mm thick. Reversing them gives wrong load figures.
- Ignoring the cross bars. They add about 2–3 kg/m² — around 5–15% of the total for light gratings.
- Forgetting the galvanizing. GI grating is heavier than the black weight shown on many charts.
- Laying bearing bars the wrong way. Bearing bars must span between supports. Turned 90°, the grating carries almost nothing.
- Using weight to judge strength. A taller, thinner bar can be stronger and lighter than a shorter, thicker one.
- Leaving out banding and cut-outs when estimating transport or crane loads.
Limitations of this guide
- All weights are theoretical. Rolling tolerances, cross bar type, serrations and actual zinc thickness change the real weight by a few percent.
- The 8% galvanizing figure is a planning allowance, not a standard value.
- The load table is a simplified hand calculation for uniform load on a simple span. It does not cover concentrated loads, vehicle wheels, impact, fatigue or serrated bars.
- Grating for public, industrial or vehicle use should be selected by a qualified engineer using the supplier's tested data.
Frequently asked questions
What is the weight of GI grating per square metre?
It depends on bar size and pitch. Common sizes weigh about 20–60 kg/m². For example, 25 × 5 @ 30 × 100 is about 38 kg/m² galvanized and 32 × 5 @ 30 × 100 is about 48 kg/m² galvanized.
What is the formula for grating weight?
Weight (kg/m²) = 7.85 × H × t ÷ P + 7.85 × A ÷ C, with all dimensions in mm. Multiply by about 1.08 to estimate galvanized weight.
What does 30 × 100 mean in grating?
Bearing bars are at 30 mm centres and cross bars are at 100 mm centres. It is the most common mesh pattern for walkway grating.
How much does a 1 × 6 m grating panel weigh?
A 1 × 6 m panel of 32 × 5 @ 30 × 100 weighs about 271 kg black and about 292 kg galvanized, including banding on the two ends.
Is MS grating the same as GI grating?
The steel grid is the same. MS (mild steel) grating is left black or painted; GI grating is hot-dip galvanized, which adds zinc protection and a few percent of weight.
Which is stronger: 32 × 5 or 25 × 5 grating?
32 × 5. Bending strength rises with the square of bar height, so 32 × 5 has about 1.6 times the strength of 25 × 5 at the same pitch and span.
Does serrated grating weigh more than plain grating?
No — it is slightly lighter, because steel is removed to form the notches. Its load capacity is also slightly lower.
Which standard covers steel open bar grating?
In the UK and many Gulf projects, BS 4592-0 and BS 4592-1 cover industrial flooring and open bar gratings. In the US, the NAAMM MBG manuals are used. Galvanizing is usually specified to ISO 1461 or ASTM A123.
Conclusion
Grating weight is easy to work out once you know four numbers: bearing bar height, thickness, pitch and cross bar size. Use 7.85 × H × t ÷ P + 7.85 × A ÷ C for black weight, add about 8% for galvanizing, then multiply by panel area. For strength, remember that bar height and span matter far more than weight — check the supplier's load tables before you order.
Need GI grating in Dubai or the UAE? SteelCal supplies hot-dip galvanized grating from Dubai Industrial City. Send your panel size, bearing bar and quantity for a quotation.
Related SteelCal guides
- How to calculate metal weight: formulas and examples
- MS flat bar sizes and weights
- Chequered plate for stair nosings and floors
- Expanded metal mesh
- Steel size and weight chart
References
- NAAMM MBG 534-14, Metal Bar Grating Engineering Design Manual, National Association of Architectural Metal Manufacturers (allowable stresses, load and deflection formulas, 0.25 in pedestrian deflection guidance).
- BS 4592-0:2006 and BS 4592-1:2006, Industrial type flooring and stair treads — Metal open bar gratings, British Standards Institution.
- EN ISO 1461, Hot dip galvanized coatings on fabricated iron and steel articles — minimum coating thickness values as published by Galvanizers Association (UK).
Published by SteelCal.com — Ibnee Younus Building & Construction Materials Trading Co. LLC, Dubai Industrial City, UAE. Weights in this article were calculated by SteelCal from the formulas shown; they are theoretical values for estimating.
Featured photo: Unsplash (free to use under the Unsplash License).
Comments are closed.